Balkmonterade utdragsenheter
Våra utdragsenheter levereras monterade och funktionstestade
De tillverkas i vår egen fabrik på Orust vilket gör att vi har full kontroll över kvalitet och konstruktion
Funktioner
Klicka på knapparna och läs mer om funktioner
Välj mellan 70% eller 100% utdragskapacitet
Easy to install – simply secure to the crossbeams using 4 bolts
Maximum loading capacities from 200 kg to 1500 kg per unit
The fact that we use high-quality certified steel with known and consistent properties also contributes to safety
Fitting double ball bearings at the front gives lower
profiles and means that our pull-out units run smoothly with low handling power, even with high load factors.
Our pull-out units are supplied ready
assembled and fully tested.
Beam-mounted (BM) units are mounted on the cross-beams between the pallet racking uprights. The lower frame of the pull-out unit is bolted to the beams and the upper frame slides out carrying the pallet with it.
Normalt hanteras pall på enheterna, men med ett plåtplan blir det möjligt att lagra plastlådor, kartonger eller lösa detaljer direkt på enheten. Att kunna dra ut pallen ur pallstället ger säker, snabb och enkel tillgång till dina komponenter.
BM units are available in a range of capacities up to 1500kg and in a variety of formats to suit your requirements. De kan användas till alla pallstorlekar och typer – trä, stål eller plast spelar ingen roll. The base frame BM unit is for pallets.
Video
Units for manual handling
The loading surface consists of a galvanised steel sheet with raised
edges, perfect for Euro crates, boxes, tools etc.
With a wooden frame directly on the unit – you get a economical, quick and effective storage presented in an ergonomical fromat. The wooden frame serves as a powerful and affordable frame that is possible to compartmentalized by dividers.
Unit locks when pushed back into the rack.
Accessories for Beam-mounted units
Click the buttons and read more about accessories
A pull-out unit locking system avoids the danger of the cross-beam
being overloaded. The lock is available for two, three or four pallet-width
bays and locks one section at the time. When one unit is pulled out, the
others are locked. Normally this lock is placed at the back. We also have
a lock that is placed under the unit; this is typically used when there isn’t
enough room behind, for example if you have double pallet racks, or if
you load from the rear.
Rear pallet stop
An angle profile which can be fitted to the back of the unit to stop the pallet sliding too far back when the unit is pushed in. Supplied ready fitted to unit.
Feet for BM unit
For mounting BM units off the floor. Two sizes, for up to 800kg units and up
to 1000kg units. Height 150mm, galvanized steel.
Foot-operated lock release catch Recommended for units installed close to floor level.
Floor mounting profiles
For mounting BM units close to the floor. Three versions,
for short-side and long-side forward handling up to
1000kg, and for short-side handling up to 1500kg.
Height 35mm, galvanized steel.
Lock in extended position
Sometimes you want to lock the unit when it´s pulled out, for example while picking
or loading goods. This lock is also useful with narrow aisles, so that when the unit is
fully pulled out you can load a pallet from the side.
Steel shelf panel
This accessory covers the top of the
pull-out unit so that smaller items such as
plastic bins or cartons can’t slip through.
You can still use the unit for pallets, so you
have fully flexible storage.
Material: Galvanized mild steel
Front pallet stop
A pair of steel plates for mounting either side
of the unit at the front, acts as a safety stop
when loading a pallet from the rear.
Handles for beam-mounted units
The units have integrated horizontal locking handles. Side handles are recommended for BM pull-out units when they are fitted in the lower and mid-range of picking heights, to save bending. Two types are available, Standard and Easy Action™ (EA). Both
types of handle are available in a range of lengths.
Det finns tre valmöjligheter för att dra ut hyllplanen. The choice of 70% or 100% extension capacity depends mainly on whether or not it’s easy to pick your items from the back of the unit. The choice of one- or two-way action depends on whether you want to load and pick from one side only or to have equal access from both sides..
70% utdragsbarhet ett håll
Det mest ekonomiska valet
For most applications, 70% extension gives sufficientaccess to all your goods
100% utdragsbarhet ett håll
För maximal åtkomst:
If you have small items at the back of the
shelf or if you need to use an overhead
crane for loading and picking, 100%
extension makes life much easier!
70% utdragsbarhet åt två håll
Åtkomst på bägge sidor:
With shelves that can be pulled out in either direction, you have the possibility of operators at separate work positions accessing the same stores, or at an assembly station one side can be used for picking and the other for restocking.
Antal hyllplan
The tables show youwhat clearances to expect
between shelves for a givennumber of shelves per unit, med jämn fördelning. Hyllplanen kan placeras i individuella kombinationer om såönskas. För mer detaljerad information, please consult product data sheets or contact us.
Tippskyddslås
Unless you bolt the CSU to the floor, it is essential to add a shelf lock, which prevents more than one shelf being pulled out at once, so the unit doesn’t get tipped over
Important Safety Information
- -The pallet racking must be bolted to the floor (see
manufactures instructions) - -Rear cross beam must be bolted to the pallet racking
uprights (minimum dimension M8) - -The pull-out unit must be bolted to the rear cross-beam
with the fitting kit provided - -Each pair of cross beams must have load capacity
according to table on next page - -Only one pull-out unit in each section (pair of cross
beams) may be pulled out at a time. - -With using pull-out units in different levels of one rack only
in one level a pull-out unit be pulled-out at the same time - -See separate notice for maximum evenly distributed
loading weight per pull-out unit - -Directly after using the pull-out unit, it must be pushed
back – check that it’s locked!